Category: CTD Methods
-
CTD Data Processing Protocol
Please note, the processing methods described use SIO-CalCOFI-developed software (DECODR & BtlVsCTD) to merge and correct Seabird 911+ CTD data with bottle samples. The Seasoft portion of our data processing protocol follow their recommended settings for our 911+ v2 CTD & deck unit. “Sta.csvs” are bottle data collected at each station cast combined with 1m binavg…
-
Satlantic ISUS Operation
Setting up and using the ISUS with Seabird CTD 1). Connect the ISUS Analog Out port to a 6-pin CTD port – we use voltage channel 6 on a universal Y-cable, allowing pH to occupy channel 7. Map that port in Seasave as user-polynomial; under the user-polynomial, enter: A0 = – 7.1168, A1 = 27.155. …
-
CTD System
A Sea-Bird Electronics 911plus V2 CTD collects vertical profile data at every CalCOFI station. In addition to being a dual TCO (temperature, conductivity, and oxygen) system, the CTD also interfaces with a transmissometer, fluorometer, PAR/SPAR meters, altimeter, nitrate, and pH sensor. Connected to a shipboard data-acquisition computer through an electronically-conductive winch wire, sensor data are…
-
SeasaveV7 Setup & Data Acquisition
SeasaveV7 on Windows 7 CTD Operator’s Cookbook Turn on deck unit and be sure what is displayed on the front LED panel are non-zeros. In Seasave v7, select RealTimeData/Start from the menu. Do Not store data on disk immediately so select “Begin archiving data when the start archiving command is sent”. Click [Select Output Data…